Smart Home Site Survey Malaysia: A Room-by-Room Checklist
A smart home site survey Malaysia checklist: how to record neutral presence, back box depth and circuit ID at every switch position, before you quote.
Answer up front — Work down the job the client described, not the product list. Each row below names the product from the current Malaysian range, what has to be true at the wall or fixing point, and the limitation that turns into a callback if you skip it. Model choice is the easy part; the neutral, the box depth and the load decide whether it goes in. Partner pricing is issued to registered partners through the programme, so this guide carries no prices.
The installer resource hub is the catalogue. This is the decision aid. Standing in a bedroom at 4pm with a torch and a client who wants the hallway light on when they walk in, start at the row, not at the catalogue.
| Job the client wants | Product | What it needs at the wall or the point | The limitation that bites |
|---|---|---|---|
| Control an existing light | Smart Wall Switch Z1 Pro (SEA wall box format); Single Switch Module T1, With Neutral or No Neutral, behind an existing switch or at the rose; Dual Relay Module T2 for two circuits | What the datasheet requires at that position, and box depth to take the device | A conventional replacement expects live and neutral in the box. Loop-in wiring usually gives you live and switched live and nothing else — that is what the No Neutral module is for. Fixed electrical work: registered wireman, Act 447 |
| Dim a light | Ceiling Light T1M, LED Bulb T2, Spotlight T2 Pro or T2 Lite, LED Strip T1 | Mains at the fitting; the wall switch can stay conventional or go smart | The current Malaysian range has no in-wall dimmer for SEA boxes — brightness control sits at the fitting, not at the plate. Ask us if a job needs something else. Driver and minimum load are a separate question before you promise a dim — see LED load and dimming compatibility |
| Control a fan | A switch or relay module rated for the fan's motor load — confirm the model with us | Neutral where required, box depth, and a device rated for an inductive load | On/off is the easy part. Fan speed control and light dimming are two different conversations, and neither is solved by a lighting switch |
| Control an aircon or water heater | Smart 20A Switch H1 (SEA Version) | A 20A circuit, what the datasheet requires at the box, and a load that is meant to be interrupted | It is a relay: on and off, not the unit's own settings. Anything past on/off is infrared — a hub with an IR blaster such as Hub M3 or M200, not a switch. Load classes are in aircon, water heater and 20A circuits |
| Motorise a curtain | Mains track motors: Curtain Controller (SEA Version) or Curtain Controller C3. Battery clip-on: Curtain Driver E1 (track or rod version) on an existing track or rod | Mains motors need a supply at the window head and room in the curtain box. The E1 needs no socket, but the existing track or rod has to suit it | The rail, the fabric weight and the internal space of the box decide whether it goes in cleanly. Battery units need a charging plan. See motorised curtains and blinds installation |
| Secure a door | Smart Lock D200i (face recognition, infrared camera for night use, 8 unlock modes, replaceable Li-ion battery); Smart Lock U400 (hands-free unlock on approach, plus fingerprint and passcode); Smart Lock U200 Lite (retrofits an existing deadbolt); Smart Gate Lock U500 for gates | No mains at the door. Door prep, strike, and a fit that suits the door | A smart lock is a door job before it is a product job — thickness, lock body, spindle and rebate decide it. See smart lock installation across door types |
| Detect a door opening | Door and Window Sensor P2 (Matter over Thread) or Door and Window Sensor T1 (Zigbee) | No mains. Adhesive or screw fix, magnet aligned to the body | Battery device. The P2 needs a Matter controller such as Hub M3 or M200. Magnet gap is a spec — take it from the datasheet |
| Detect motion | Motion Sensor P1 | No mains | Battery only, so it does not act as a Zigbee router. PIR is line-of-sight: someone standing in the doorway is not the room being occupied |
| Detect presence | Presence Multi-Sensor FP300 (battery, 5-in-1 sensing); Presence Sensor FP2 or FP1E where the job suits them | Check the power requirement on each datasheet | Placement decides the result more than the model. Battery units need a replacement plan |
| Detect a leak, shut the water off | Water Leak Sensor T1, triggering a motorised shut-off valve | Plumbing access at the isolating valve for the valve itself | The valve is the job, and plumbing is a separate trade unless you hold the licence. See water leak, gas, smoke and valve protection |
| Auto-feed a pet | Smart Pet Feeder C1 | Power at the feeder per its datasheet, and a working signal path to a hub | Hub reach. A feeder behind a wall with the hub at the other end of the house is an offline feeder. Do not sell a feature you cannot source |
| Control an appliance | Power Plug H2 UK (plug-in, UK Type G); Wall Outlet H2 UK (in-wall socket); Smart 20A Switch H1 (SEA Version) for a 20A load | A standard socket for the plug; a suitable box and a registered wireman for the outlet; a 20A circuit for the 20A switch | Match the device rating to the appliance. A plug-in device is not the answer for an aircon or water heater circuit |
| Control a whole scene from a wall | Battery, no wiring: Wireless Remote Switch H1, Wireless Mini Switch T1, Cube T1 Pro. Mains panels: MagicPad S1 Plus (SEA&ME Version), Panel Hub S1 Plus, Panel Switch S100 | Battery switches need nothing at the wall. Panels are mains-fed in-wall devices that need what the datasheet specifies and the box to suit | Two problem classes on one row — quote the class, not the brand. For any panel, confirm the box format and depth before you commit |
| Be the hub | Panel Hub S1 Plus (in-wall touchscreen, built-in Zigbee hub); Hub M3 (Matter controller, Thread border router, IR blaster, PoE or USB-C); Hub M200 (Matter controller, IR, PoE or USB-C); Hub M100 (plug-in USB, low-cost or extra hub); camera hubs G3, G5 Pro and Doorbell Camera Hub G410 | Mains, and a position with signal rather than a convenient socket | The S1 Plus is a Zigbee hub but not a Matter controller. Matter accessories — including Matter over Thread — are added through a Matter controller such as Hub M3, set up in Aqara Home first, and can then be controlled from the S1 Plus. See hub placement, Wi-Fi coverage and power backup |
Three site facts decide most of the rows above. Neutral at the switch box — loop-in lighting wiring sends live and neutral up to the rose and drops only a switch wire down, so the box has live plus switched live, and houses are inconsistent internally because parts were altered at different times. Open the boxes and look; that is what the room-by-room survey is for. The load — a relay fine for a lighting circuit is not automatically fine for an aircon. Box depth — a smart module plus the existing conductors may not go into a shallow back box, and that belongs in the quote, not in a contingency you absorb.
The second question is not which product, but who is allowed to touch what. It belongs in your quote as scope.
| Job | Fixed mains work at the position? | Who does it |
|---|---|---|
| Wall switch or relay module — Z1 Pro, Single Switch Module T1, Dual Relay Module T2 | Yes | Suruhanjaya Tenaga-registered wireman (Act 447) |
| Panels — MagicPad S1 Plus, Panel Hub S1 Plus, Panel Switch S100 | Yes | Registered wireman, box format and depth first |
| 20A switch on an aircon or water heater circuit | Yes | Registered wireman, right circuit |
| In-wall socket — Wall Outlet H2 UK | Yes | Registered wireman |
| Ceiling light or LED fitting — T1M, Spotlight T2, LED Strip T1 | Yes, at the fitting | Registered wireman |
| Mains curtain motor — Curtain Controller (SEA Version), C3 | Yes, if the supply is new | Registered wireman for the supply |
| Battery curtain driver — Curtain Driver E1 | No | Mounting and pairing only |
| Sensors — Motion P1, Door and Window P2 or T1, FP300, Water Leak T1 | No | Mounting and pairing only |
| Locks — D200i, U400, U200 Lite, U500 | No | Door prep is carpentry and mechanical |
| Doorbell and camera hubs — G410, G5 Pro, G3 | Depends on the power option | Mounting and network; a wireman if a new supply is needed |
| Motorised water shut-off valve | No — plumbing access | A plumber, unless you are one |
Plug-in and sensor work is safe to delegate and quick to price. In-wall mains wiring is where a registered wireman, a SIRIM-labelled product with Energy Commission approval and a written scope all matter. A botched neutral is a fire and shock risk, and unlicensed mains work can void the client's home insurance.
Confirm the exact SKU against the current datasheet on the day you commit, and take pricing from the current partner price list rather than memory. Partner pricing and terms are provided to registered partners through the programme; a quote built on a remembered number is a dispute waiting for a cause. If a job needs something this table does not cover, ask us before it goes in a quote.

A smart home site survey Malaysia checklist: how to record neutral presence, back box depth and circuit ID at every switch position, before you quote.

From the official Aqara Malaysia distributor: the current range, which products need a neutral, back box and gang needs, aircon loads and local support.

A smart dimmer LED compatibility guide: minimum load, driver behaviour, flicker causes, the 20A rule for aircon and water heaters, and the capacitor fix.
Tell us about your space. Our B2B team will reply within one business day with a recommended setup and quotation.
WhatsApp us →
[email protected]
+603-5880 5486