Answer up front — Work down the job the client described, not the product list. Each row below names the product from the current Malaysian range, what has to be true at the wall or fixing point, and the limitation that turns into a callback if you skip it. Model choice is the easy part; the neutral, the box depth and the load decide whether it goes in. Partner pricing is issued to registered partners through the programme, so this guide carries no prices.

The installer resource hub is the catalogue. This is the decision aid. Standing in a bedroom at 4pm with a torch and a client who wants the hallway light on when they walk in, start at the row, not at the catalogue.

The decision table

Job the client wantsProductWhat it needs at the wall or the pointThe limitation that bites
Control an existing lightSmart Wall Switch Z1 Pro (SEA wall box format); Single Switch Module T1, With Neutral or No Neutral, behind an existing switch or at the rose; Dual Relay Module T2 for two circuitsWhat the datasheet requires at that position, and box depth to take the deviceA conventional replacement expects live and neutral in the box. Loop-in wiring usually gives you live and switched live and nothing else — that is what the No Neutral module is for. Fixed electrical work: registered wireman, Act 447
Dim a lightCeiling Light T1M, LED Bulb T2, Spotlight T2 Pro or T2 Lite, LED Strip T1Mains at the fitting; the wall switch can stay conventional or go smartThe current Malaysian range has no in-wall dimmer for SEA boxes — brightness control sits at the fitting, not at the plate. Ask us if a job needs something else. Driver and minimum load are a separate question before you promise a dim — see LED load and dimming compatibility
Control a fanA switch or relay module rated for the fan's motor load — confirm the model with usNeutral where required, box depth, and a device rated for an inductive loadOn/off is the easy part. Fan speed control and light dimming are two different conversations, and neither is solved by a lighting switch
Control an aircon or water heaterSmart 20A Switch H1 (SEA Version)A 20A circuit, what the datasheet requires at the box, and a load that is meant to be interruptedIt is a relay: on and off, not the unit's own settings. Anything past on/off is infrared — a hub with an IR blaster such as Hub M3 or M200, not a switch. Load classes are in aircon, water heater and 20A circuits
Motorise a curtainMains track motors: Curtain Controller (SEA Version) or Curtain Controller C3. Battery clip-on: Curtain Driver E1 (track or rod version) on an existing track or rodMains motors need a supply at the window head and room in the curtain box. The E1 needs no socket, but the existing track or rod has to suit itThe rail, the fabric weight and the internal space of the box decide whether it goes in cleanly. Battery units need a charging plan. See motorised curtains and blinds installation
Secure a doorSmart Lock D200i (face recognition, infrared camera for night use, 8 unlock modes, replaceable Li-ion battery); Smart Lock U400 (hands-free unlock on approach, plus fingerprint and passcode); Smart Lock U200 Lite (retrofits an existing deadbolt); Smart Gate Lock U500 for gatesNo mains at the door. Door prep, strike, and a fit that suits the doorA smart lock is a door job before it is a product job — thickness, lock body, spindle and rebate decide it. See smart lock installation across door types
Detect a door openingDoor and Window Sensor P2 (Matter over Thread) or Door and Window Sensor T1 (Zigbee)No mains. Adhesive or screw fix, magnet aligned to the bodyBattery device. The P2 needs a Matter controller such as Hub M3 or M200. Magnet gap is a spec — take it from the datasheet
Detect motionMotion Sensor P1No mainsBattery only, so it does not act as a Zigbee router. PIR is line-of-sight: someone standing in the doorway is not the room being occupied
Detect presencePresence Multi-Sensor FP300 (battery, 5-in-1 sensing); Presence Sensor FP2 or FP1E where the job suits themCheck the power requirement on each datasheetPlacement decides the result more than the model. Battery units need a replacement plan
Detect a leak, shut the water offWater Leak Sensor T1, triggering a motorised shut-off valvePlumbing access at the isolating valve for the valve itselfThe valve is the job, and plumbing is a separate trade unless you hold the licence. See water leak, gas, smoke and valve protection
Auto-feed a petSmart Pet Feeder C1Power at the feeder per its datasheet, and a working signal path to a hubHub reach. A feeder behind a wall with the hub at the other end of the house is an offline feeder. Do not sell a feature you cannot source
Control an appliancePower Plug H2 UK (plug-in, UK Type G); Wall Outlet H2 UK (in-wall socket); Smart 20A Switch H1 (SEA Version) for a 20A loadA standard socket for the plug; a suitable box and a registered wireman for the outlet; a 20A circuit for the 20A switchMatch the device rating to the appliance. A plug-in device is not the answer for an aircon or water heater circuit
Control a whole scene from a wallBattery, no wiring: Wireless Remote Switch H1, Wireless Mini Switch T1, Cube T1 Pro. Mains panels: MagicPad S1 Plus (SEA&ME Version), Panel Hub S1 Plus, Panel Switch S100Battery switches need nothing at the wall. Panels are mains-fed in-wall devices that need what the datasheet specifies and the box to suitTwo problem classes on one row — quote the class, not the brand. For any panel, confirm the box format and depth before you commit
Be the hubPanel Hub S1 Plus (in-wall touchscreen, built-in Zigbee hub); Hub M3 (Matter controller, Thread border router, IR blaster, PoE or USB-C); Hub M200 (Matter controller, IR, PoE or USB-C); Hub M100 (plug-in USB, low-cost or extra hub); camera hubs G3, G5 Pro and Doorbell Camera Hub G410Mains, and a position with signal rather than a convenient socketThe S1 Plus is a Zigbee hub but not a Matter controller. Matter accessories — including Matter over Thread — are added through a Matter controller such as Hub M3, set up in Aqara Home first, and can then be controlled from the S1 Plus. See hub placement, Wi-Fi coverage and power backup

Who does what, and what it needs at the wall

Three site facts decide most of the rows above. Neutral at the switch box — loop-in lighting wiring sends live and neutral up to the rose and drops only a switch wire down, so the box has live plus switched live, and houses are inconsistent internally because parts were altered at different times. Open the boxes and look; that is what the room-by-room survey is for. The load — a relay fine for a lighting circuit is not automatically fine for an aircon. Box depth — a smart module plus the existing conductors may not go into a shallow back box, and that belongs in the quote, not in a contingency you absorb.

The second question is not which product, but who is allowed to touch what. It belongs in your quote as scope.

JobFixed mains work at the position?Who does it
Wall switch or relay module — Z1 Pro, Single Switch Module T1, Dual Relay Module T2YesSuruhanjaya Tenaga-registered wireman (Act 447)
Panels — MagicPad S1 Plus, Panel Hub S1 Plus, Panel Switch S100YesRegistered wireman, box format and depth first
20A switch on an aircon or water heater circuitYesRegistered wireman, right circuit
In-wall socket — Wall Outlet H2 UKYesRegistered wireman
Ceiling light or LED fitting — T1M, Spotlight T2, LED Strip T1Yes, at the fittingRegistered wireman
Mains curtain motor — Curtain Controller (SEA Version), C3Yes, if the supply is newRegistered wireman for the supply
Battery curtain driver — Curtain Driver E1NoMounting and pairing only
Sensors — Motion P1, Door and Window P2 or T1, FP300, Water Leak T1NoMounting and pairing only
Locks — D200i, U400, U200 Lite, U500NoDoor prep is carpentry and mechanical
Doorbell and camera hubs — G410, G5 Pro, G3Depends on the power optionMounting and network; a wireman if a new supply is needed
Motorised water shut-off valveNo — plumbing accessA plumber, unless you are one

Plug-in and sensor work is safe to delegate and quick to price. In-wall mains wiring is where a registered wireman, a SIRIM-labelled product with Energy Commission approval and a written scope all matter. A botched neutral is a fire and shock risk, and unlicensed mains work can void the client's home insurance.

Before you quote

Confirm the exact SKU against the current datasheet on the day you commit, and take pricing from the current partner price list rather than memory. Partner pricing and terms are provided to registered partners through the programme; a quote built on a remembered number is a dispute waiting for a cause. If a job needs something this table does not cover, ask us before it goes in a quote.